Related Products
Teseq NSG 4070C Test System for Conducted and Radiated Immunity
- Class A power amplifier module can be integrated for different applications:
- 35 W, 150 kHz to 230 MHz;
- 40 W, 10 kHz to 400 MHz;
AE Techron 7224 Power Amplifier | DC - 300kHz, 900VA
- Frequency bandwidth of DC to 300 kHz at rated power.
- Continuous output of over 1,100 watts RMS at 4 ohms.
- 40 mSec pulses of up to 52 amperes peak into a 0.5 ohm load.
EMC Partner MIL3000 Military Test System
- Exceeds maximum test levels in MIL-STD-461
- One coupler for tests (CS115 & CS116)
- Test report data stored in MIL3000, accessible via USB or Ethernet
EM Test CWS 500N1 Continuous Wave Simulator, 80W
- Signal generator 9kHz to 1GHz
- Amplitude modulation: 1Hz to 3kHz (0% to 95%)
- Pulse modulation: 1Hz - 1kHz (10% to 90%)
AE Techron 3110 Standards Waveform Generator
- Includes a large library of Automotive and Aviation Standards’ test routines--complete list available as Supplemental Document under Datasheet on left
- Drag and drop interface makes it easy to modify existing tests or build new waveform sequences
- Loop entire tests or test sections; repeat loops with increments of up to four variables
Schwarzbeck CDN-M5PE-32A-1000V
- Part of the coupling decoupling network series
- For conducted common mode immunity testing according to IEC 61000-4-6
- Frequency range of 150 kHz to 230 MHz
Fischer Custom Communications F-130A Bulk Current Injector Probe
- Broad band high efficiency injection probe
- Frequency range of 1 MHz to 700 MHz
- Insertion loss of 6 dB or less
Prâna IP-DR250 Bulk Current Injection Probe
- Broadband (instantaneous single band) : 10 kHz – 400 MHz
- Frequency extension between 4kHz to 10kHz possible with limited power specifications
- Typical power: 500 W CW
Solar 7541-1 Spike Receptor Probe
- Spike receptor probe (calibrated for use with oscilloscope)
- The receptor probe is assembled with a hinged construction
- Includes a calibrating resistor mounted in the housing
Com-Power CDN-AF8 Coupling/Decoupling Network (CDN)
Solar 8850-1 Sweep Generator for MIL-STD-461 CS01/CS101
- Manual or automatic frequency sweep from 30 Hz to 100KHz
- Digital display of frequency and output voltage level or injection voltage level
- Remote sensing of voltage being injected into the Equipment Under Test
Teseq NSG 4060 Low Frequency Immunity Test System
- Signal generator and integrated power amplifier 15 Hz to 150 kHz
- Meets IEC / EN 61000-4-16 in combination with the Extension Unit
- Meets IEC / EN 61000-4-19 and other standards
Tektronix TCP303
- Easy Current Measurements
- Probe Connects Directly to TDS Scope through TEKPROBE™ BNC Interface
- Split Core Construction for Easy Circuit Connection
Montena EMP10K-5-500 Short Pulse Generator | 10 kV
- Short pulse generator
- Meets MIL-STD188-125-1/2 standards
- Generates short-duration double exponential current pulses
AE Techron T1000 Magnetic-Field Susceptibility Transformer
- Up to 100ARMS secondary current.
- Exceeds AF Magnetic Field test requirements of DO 160 Section 19 and Boeing D6-16050-5 Section 7.2.2.
- Circuit breaker protected from over-current.
Com-Power CDN-M225E Coupling/Decoupling Network (CDN)
- Frequency Range - 150 kHz - 230 MHz
- Meets EN 61000-4-6 requirements
- Current Rating: 25 Amps
Pearson Electronics 3525 Current Monitor | 5 Hz – 15 MHz
- 0.1 V/A +1/-0% sensitivity
- 50 Ω output resistance
- Maximum peak current of 5000 A
BOLAB 100-TS Series | DC – 200 kHz, 400 W – 18000 W
- DC to 200 kHz full range bandwidth
- Rise time / fall time up to 100 V/µs
- Arbitrary function with 1 Million memory data points
Amplifier Research CI00402 RF Conducted Immunity System
- Fully self-contained state of the art system designed to test RF conducted immunity
- The system contains a signal generator a spectrum analyzer a 100W nominal AR amplifier a 10 kHz to 400 MHz directional coupler emcware® control software
- a signal generator
Com-Power CLCE-1032 RF Current Probe | 9 kHz – 1000 MHz
- Frequency range of 9 kHz to 1000 MHz
- Suitable for CISPR, MIL-STD-461, and DO-160
- Individual calibration
Frankonia CIT-10 Compact Immunity Test System, 10 kHz - 400 MHz
- Conducted RF immunity tests acc. to IEC/EN 61000-4-6 and BCI tests acc. to ISO 11452-4 and MIL–STD 461E
- Signal generator, RF-power amplifier, RF-power meter and directional coupler (optional) in one 19”-case
- Stand-alone operation possible with optional available netbook
AH Systems BCP-510 Broadband Current Probe | 20Hz - 1MHz
- Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
- Individually Calibrated (Transfer Impedance calibration included)
- Split Type Clamp-on Design
Solar 7399-2 2,500 Volt Spike Generator for MIL-STD-1399
- Repetitive spikes up to 2500 volts peak at two pulses per minute.
- Single non-synchronous spike actuated by a push button on the panel.
- Sync functions provide for placing the spike on the power frequency waveform of 50, 60 or 400 Hz power lines. The spike can be moved to any point of the sine wave from 0 to 360°
Pacific Power 3150AFX AC & DC Programmable Power Source
- AC output, DC output, AC+DC output
- DC, 15 to 1,200 Hz frequency range
- Single, constant power mode 300V L-N/520V L-L/425Vdc voltage range offers wider operating range