Related Products
Amplifier Research CI00250A RF Conducted Immunity System
Teseq NSG 4070C Test System for Conducted and Radiated Immunity
- Class A power amplifier module can be integrated for different applications:
- 35 W, 150 kHz to 230 MHz;
- 40 W, 10 kHz to 400 MHz;
AE Techron 7224 Power Amplifier | DC - 300kHz, 900VA
- Frequency bandwidth of DC to 300 kHz at rated power.
- Continuous output of over 1,100 watts RMS at 4 ohms.
- 40 mSec pulses of up to 52 amperes peak into a 0.5 ohm load.
EM Test CWS 500N1 Continuous Wave Simulator, 80W
- Signal generator 9kHz to 1GHz
- Amplitude modulation: 1Hz to 3kHz (0% to 95%)
- Pulse modulation: 1Hz - 1kHz (10% to 90%)
AE Techron 3110 Standards Waveform Generator
- Includes a large library of Automotive and Aviation Standards’ test routines--complete list available as Supplemental Document under Datasheet on left
- Drag and drop interface makes it easy to modify existing tests or build new waveform sequences
- Loop entire tests or test sections; repeat loops with increments of up to four variables
Schwarzbeck CDN-M5PE-32A-1000V
- Part of the coupling decoupling network series
- For conducted common mode immunity testing according to IEC 61000-4-6
- Frequency range of 150 kHz to 230 MHz
Fischer Custom Communications F-130A Bulk Current Injector Probe
- Broad band high efficiency injection probe
- Frequency range of 1 MHz to 700 MHz
- Insertion loss of 6 dB or less
Prâna IP-DR250 Bulk Current Injection Probe
- Broadband (instantaneous single band) : 10 kHz – 400 MHz
- Frequency extension between 4kHz to 10kHz possible with limited power specifications
- Typical power: 500 W CW
Solar 7541-1 Spike Receptor Probe
- Spike receptor probe (calibrated for use with oscilloscope)
- The receptor probe is assembled with a hinged construction
- Includes a calibrating resistor mounted in the housing
Com-Power CDN-AF8 Coupling/Decoupling Network (CDN)
Teseq NSG 4060 Low Frequency Immunity Test System
- Signal generator and integrated power amplifier 15 Hz to 150 kHz
- Meets IEC / EN 61000-4-16 in combination with the Extension Unit
- Meets IEC / EN 61000-4-19 and other standards
Tektronix TCP303
- Easy Current Measurements
- Probe Connects Directly to TDS Scope through TEKPROBE™ BNC Interface
- Split Core Construction for Easy Circuit Connection
AE Techron T1000 Magnetic-Field Susceptibility Transformer
- Up to 100ARMS secondary current.
- Exceeds AF Magnetic Field test requirements of DO 160 Section 19 and Boeing D6-16050-5 Section 7.2.2.
- Circuit breaker protected from over-current.
Com-Power CDN-M225E Coupling/Decoupling Network (CDN)
- Frequency Range - 150 kHz - 230 MHz
- Meets EN 61000-4-6 requirements
- Current Rating: 25 Amps
Pearson Electronics 3525 Current Monitor | 5 Hz – 15 MHz
- 0.1 V/A +1/-0% sensitivity
- 50 Ω output resistance
- Maximum peak current of 5000 A
BOLAB 100-TS Series | DC – 200 kHz, 400 W – 18000 W
- DC to 200 kHz full range bandwidth
- Rise time / fall time up to 100 V/µs
- Arbitrary function with 1 Million memory data points
Amplifier Research CI00402 RF Conducted Immunity System
- Fully self-contained state of the art system designed to test RF conducted immunity
- The system contains a signal generator a spectrum analyzer a 100W nominal AR amplifier a 10 kHz to 400 MHz directional coupler emcware® control software
- a signal generator
Com-Power CLCE-1032 RF Current Probe | 9 kHz – 1000 MHz
- Frequency range of 9 kHz to 1000 MHz
- Suitable for CISPR, MIL-STD-461, and DO-160
- Individual calibration
Frankonia CIT-10 Compact Immunity Test System, 10 kHz - 400 MHz
- Conducted RF immunity tests acc. to IEC/EN 61000-4-6 and BCI tests acc. to ISO 11452-4 and MIL–STD 461E
- Signal generator, RF-power amplifier, RF-power meter and directional coupler (optional) in one 19”-case
- Stand-alone operation possible with optional available netbook
AH Systems BCP-510 Broadband Current Probe | 20Hz - 1MHz
- Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
- Individually Calibrated (Transfer Impedance calibration included)
- Split Type Clamp-on Design
EM Test CWS 500N3 Low Frequency Simulator 10 Hz - 250 kHz
Schwarzbeck CDN-AF2
- Part of the coupling decoupling network series
- For conducted common mode immunity testing according to IEC 61000-4-6
- Frequency range of 0.15 - 230 MHz
Solar 9120-1N Injection Probe
- Injection probe
- Split toroidal design for easy clamping onto test wires
- Calibrated for insertion loss and transfer impedance
AH Systems BCP-520 Broadband Current | 10kHz - 500MHz
- Individually Calibrated (Transfer Impedance calibration included)
- High current conducted emissions measurements without saturation
- High Current Capability
Com-Power CDN-M125E Couplers Coaxial
- Frequency Range - 150 kHz -230 MHz
- Meets EN 61000-4-6 requirements
- Current Rating: up to 25 Amps