Related Products
Schloder CDG7000 Conducted Disturbances Test System
- Compact device
- Consists of an RF signal generator, an RF-power amplifier, a 3-channel RF voltmeter, and a directional coupler
- RF power amplifier is available in three different models
Solar 7541-1 Spike Receptor Probe
- Spike receptor probe (calibrated for use with oscilloscope)
- The receptor probe is assembled with a hinged construction
- Includes a calibrating resistor mounted in the housing
Com-Power CDN-AF8 Coupling/Decoupling Network (CDN)
- Frequency Range - 150 kHz - 80 MHz
- For Signal Lines
- Meets EN 61000-4-6 requirements
Solar 8850-1 Sweep Generator for MIL-STD-461 CS01/CS101
- Manual or automatic frequency sweep from 30 Hz to 100KHz
- Digital display of frequency and output voltage level or injection voltage level
- Remote sensing of voltage being injected into the Equipment Under Test
Tektronix TCP303
- Easy Current Measurements
- Probe Connects Directly to TDS Scope through TEKPROBE™ BNC Interface
- Split Core Construction for Easy Circuit Connection
Montena EMP10K-5-500 Short Pulse Generator | 10 kV
- Short pulse generator
- Meets MIL-STD188-125-1/2 standards
- Generates short-duration double exponential current pulses
Com-Power CDN-M225E Coupling/Decoupling Network (CDN)
- Frequency Range - 150 kHz - 230 MHz
- Meets EN 61000-4-6 requirements
- Current Rating: 25 Amps
Pearson Electronics 3525 Current Monitor | 5 Hz – 15 MHz
- 0.1 V/A +1/-0% sensitivity
- 50 Ω output resistance
- Maximum peak current of 5000 A
AE Techron T1000 Magnetic-Field Susceptibility Transformer
- Up to 100ARMS secondary current.
- Exceeds AF Magnetic Field test requirements of DO 160 Section 19 and Boeing D6-16050-5 Section 7.2.2.
- Circuit breaker protected from over-current.
BOLAB 100-TS Series | DC – 200 kHz, 400 W – 18000 W
- DC to 200 kHz full range bandwidth
- Rise time / fall time up to 100 V/µs
- Arbitrary function with 1 Million memory data points
Amplifier Research CI00402 RF Conducted Immunity System
- Fully self-contained state of the art system designed to test RF conducted immunity
- The system contains a signal generator a spectrum analyzer a 100W nominal AR amplifier a 10 kHz to 400 MHz directional coupler emcware® control software
- a signal generator
Com-Power CLCE-1032 RF Current Probe | 9 kHz – 1000 MHz
- Frequency range of 9 kHz to 1000 MHz
- Suitable for CISPR, MIL-STD-461, and DO-160
- Individual calibration
Frankonia CIT-10 Compact Immunity Test System, 10 kHz - 400 MHz
- Conducted RF immunity tests acc. to IEC/EN 61000-4-6 and BCI tests acc. to ISO 11452-4 and MIL–STD 461E
- Signal generator, RF-power amplifier, RF-power meter and directional coupler (optional) in one 19”-case
- Stand-alone operation possible with optional available netbook
AH Systems BCP-510 Broadband Current Probe | 20Hz - 1MHz
- Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
- Individually Calibrated (Transfer Impedance calibration included)
- Split Type Clamp-on Design
Solar 7399-2 2,500 Volt Spike Generator for MIL-STD-1399
- Repetitive spikes up to 2500 volts peak at two pulses per minute.
- Single non-synchronous spike actuated by a push button on the panel.
- Sync functions provide for placing the spike on the power frequency waveform of 50, 60 or 400 Hz power lines. The spike can be moved to any point of the sine wave from 0 to 360°
Pacific Power 3150AFX AC & DC Programmable Power Source
- AC output, DC output, AC+DC output
- DC, 15 to 1,200 Hz frequency range
- Single, constant power mode 300V L-N/520V L-L/425Vdc voltage range offers wider operating range
EM Test CWS 500N3 Low Frequency Simulator 10 Hz - 250 kHz
Schwarzbeck CDN-AF2
- Part of the coupling decoupling network series
- For conducted common mode immunity testing according to IEC 61000-4-6
- Frequency range of 0.15 - 230 MHz
Solar 2854-2 Spike Generator
- Provides output levels from 10 V to more than 400 V into 5 Ω
- Adjustable pulse position on AC lines relates the transient susceptibility to real time aspects of digital systems
- Single pulse feature for controlled isolation of transient eects
Solar 9120-1N Injection Probe
- Injection probe
- Split toroidal design for easy clamping onto test wires
- Calibrated for insertion loss and transfer impedance
Montena PG1275E Surge Generator for MIL-STD 1275E
- Generator can be fully controlled by a computer through a RS232 or an USB interface
Solar 7054-2B Spike Generator
- 0° to 360°
- Periodically 50, 60 or 400 Hz Sine Wave
- Provides output levels from 10 V to 400 V into 5 Ω. Delivers more than 300 kW peak into 0.5 Ω load
AH Systems BCP-520 Broadband Current | 10kHz - 500MHz
- Individually Calibrated (Transfer Impedance calibration included)
- High current conducted emissions measurements without saturation
- High Current Capability
Solar 8282-1 Transient Pulse Generator
- Provides outputs up to 600 volts peak amplitude for the 0.15, 5.0 and 10.0 S spikes into a five ohm resistive load (low source impedance).
- A wide range of repetition rates allows spike injection in terms of the pulse rates of items being tested.
- The single pulse feature enables controlled isolation of transient effects.