Skip to Content
Alt text
Standard Overview Products Used in Testing

Standard Overview

Airbus ABD0100.1.8 safety standard covers the environmental conditions and test requirements associated with qualification. This standard specifically pertains to EMC conducted susceptibility and was developed based off of the existing RTCA/DO-160 standards.

The following test tables are included in the ABD0100 test option.
 
Power Group Description Nominal Voltage Nominal Frequency Phase Modes
Table A AC Power, Constant Frequency 115Vrms L-N 400Hz 1 Phase and 3 Phase
Table B AC Power, Constant Frequency 26Vrms L-N 400Hz 1 Phase and 3 Phase
Table C AC Power, Wide Variable Frequency 115Vrms L-N 360 – 800 Hz 1 Phase and 3 Phase
Table D Conventional DC Power Test 28 Vdc n/a n/a
Table E NBPT DC Power Test 28 Vdc n/a n/a