Related Products

Teseq NSG 4070B
- Integrated signal generator 9 kHz – 1 GHz
- 3 power meter inputs 9 kHz – 1 GHz
- Integrated class A power amplifier module for different applications: 35 W, 150 kHz – 230 MHz; 40 W, 10 kHz – 400 MHz 45 W, 9 kHz – 1 GHz; 80 W, 150 kHz


Solar 2654-2 Lightning Transient Generator System for DO-160
- The controller and power supply module
- Waveform timing
- The high voltage power supply


EMC Partner MIL-MG3 Military Test System
- Exceeds maximum test levels in MIL-STD-461
- One coupler for tests (CS115 & CS116)
- Test report data stored in MIL-MG3, accessible via USB or Ethernet


Solar 9354-2 Transient Generator for MIL-STD-461 and DO-160
- Panel-mounted digital voltmeter. Monitors the adjusted open circuit discharge voltage
- Pulse rates up to one pulse per second maximum (factory adjusted)
- Single pulse feature enables controlled isolation of transient effects


Solar 9354-1
- Panel mounted digital Voltmeter displays the open circuit discharge voltage
- Automatic or manual trigger for damped sinewave. Manual only for double exponential pulses
- Variable peak output voltage (adjustable from 0.1 to 100% of selected circuit discharge voltage


Solar Electronics 7399-3 Spike Generator
- Repetitive spikes up to 2500 V peak at two pulses per minute
- Single non-synchronous spike actuated by a pushbutton on the panel
- Sync functions provide for placing the spike on the power frequency waveform of 50, 60 or 400 Hz power lines; the spike can be moved to any point on the sine wave from 0 to 360°


Montena PPG-E1-1200 Portable Pulse Generator for MIL-STD-188-125
- A wide operating range from 50 A to 1.2 kA
- Dedicated control software application for the configuration of the generator and the measurement equipment
- Battery powered, especially designed for tests onsite


Solar 7399-2 2,500 Volt Spike Generator for MIL-STD-1399
- Repetitive spikes up to 2500 volts peak at two pulses per minute.
- Single non-synchronous spike actuated by a push button on the panel.
- Sync functions provide for placing the spike on the power frequency waveform of 50, 60 or 400 Hz power lines. The spike can be moved to any point of the sine wave from 0 to 360°


Teseq NSG 4060 Low Frequency Immunity Test System
- Signal generator and integrated power amplifier 15 Hz to 150 kHz
- Meets IEC / EN 61000-4-16 in combination with the Extension Unit
- Meets IEC / EN 61000-4-19 and other standards


Solar 8850-2 High Power Sweep Generator
- Manual or automatic frequency sweep from 30 Hz to 150 KHz
- Digital display of frequency and output voltage level or injected voltage level
- Remote sensing of voltage being injected into the Equipment Under Test


Solar Electronics 9554 Variable Frequency Modules
- Variable frequency modules
- Comes in several configurations
- Specialized module for military and aerospace applications


Solar 9355-1 for MIL-STD-461D/E CS115
- Panel-mounted digital meters monitor the adjustable charged line voltage and pulse repetition rate.
- Adjustable pulse rate from 0.6 p.p.s. to 150 p.p.s., and manual triggering via front panel push button.
- Charged line output voltage adjustable from 1.0 V to >2000 V


California Instruments CSW5550 Programmable AC/DC Power Source
- Output: 5.5kVA, 0-156/312V, 3ph
- Frequency Range: 40Hz - 5kHz
- Input Power: 187/264Vrms (3 wire), 342/457Vrms (4 wire), 3ph


Solar 7054-2B Spike Generator
- 0° to 360°
- Periodically 50, 60 or 400 Hz Sine Wave
- Provides output levels from 10 V to 400 V into 5 Ω. Delivers more than 300 kW peak into 0.5 Ω load


Solar 8282-1 Transient Pulse Generator
- Provides outputs up to 600 volts peak amplitude for the 0.15, 5.0 and 10.0 S spikes into a five ohm resistive load (low source impedance).
- A wide range of repetition rates allows spike injection in terms of the pulse rates of items being tested.
- The single pulse feature enables controlled isolation of transient effects.


Teseq Mil-Std-461 CS114 10kHz - 400 MHz Conducted Susceptibility Test System
- Signal generation: NSG 4070-0
- Modulator: included in NSG 4070-0
- Power meter: 3x included in NSG 4070-0


Solar 2854-2 Spike Generator
- Provides output levels from 10 V to more than 400 V into 5 Ω
- Adjustable pulse position on AC lines relates the transient susceptibility to real time aspects of digital systems
- Single pulse feature for controlled isolation of transient eects


Solar 8850-1 Sweep Generator for MIL-STD-461 CS01/CS101
- Manual or automatic frequency sweep from 30 Hz to 100KHz
- Digital display of frequency and output voltage level or injection voltage level
- Remote sensing of voltage being injected into the Equipment Under Test


Solar 2854-1 Transient Generator
- For MIL-STD-461F CS106 conducted transient susceptibility test
- Adjustable pulse position on AC lines relates the transient susceptibility to real time aspects of digital systems
- Single-pulse feature for controlled isolation of transient effects


Solar 7054-1 Spike Generator for MIL-STD-461 CS106
- Provides output levels from 10 volts to more than 600 volts into 5 ohms or less. Delivers more than 300 kw peak into 0.5 ohms load.
- Adjustable pulse position on a.c. lines relates the transient susceptibility to real time aspects of digital systems.
- Single pulse feature for controlled isolation of transient effects.


Solar 7054-2 Spike Generator 600 V
- 10 V to 600 V Output
- Delivers < 300 kW Peak to a .5 Ω Load
- Pulse Position on AC Lines Adjustable - Relates Transient Immunity to Real Time Aspects


Solar 6254-5S RFI Transient Generator
- Spike Amplitude: Continuously adjustable from less than 10 volts to more than 250 volts peak.
- Repetition Rate: Continuously adjustable from 0.5 to 500 p.p.s.
- Rise Time: Less than 1.0 microsecond.


Montena EMP10K-5-500 Short Pulse Generator | 10 kV
- Short pulse generator
- Meets MIL-STD188-125-1/2 standards
- Generates short-duration double exponential current pulses


Pacific Power 3150AFX AC & DC Programmable Power Source
- DC, 15 to 1,200 Hz frequency range
- Accuracy ± 0.01%
- 125 Arms / 62.5 ADC


Montena PG1275E Surge Generator for MIL-STD 1275E
- Generator can be fully controlled by a computer through a RS232 or an USB interface