Input: |
230 V +/-10%, 50/60 Hz, single phase, 30 A peak, 25 A avg. |
Output: |
0 – 50 kV AC peak, 0.1, 0.05, 0.02 and 0.01 Hz sinusoidal |
Duty: |
Continuous |
Test Capacitance: |
5.0 µF @ 0.1 Hz
10.0 µF @ 0.05 Hz
25.0 µF @ 0.02 Hz
50.0 µF @ 0.01 Hz |
Voltmeter: |
3.5″, 0 – 60 peak kV 2% FS accuracy |
Charging Current Meter: |
3.5″, 0 – 200 mA 5% FS accuracy |
Capacitance Meter: |
0 – 6 µF with x 1 and x 10 ranges |
Output Termination: |
Shielded HV x-ray and ground cable on reels – 100 ft./30 m |
Size & Weight: (W x D x H) |
Remote Control:
17 x 11 x 9.5 in., 20 lb
432 x 280 x 241 mm, 9 kg
Power Section:
20 x 14 x 27 in., 160 lb.
508 x 356 x 686 mm, 73 kg
HV Tank:
13.5 x 19 x 23 in., 310 lb.
343 x 483 x 584 mm, 141 kg
Complete Trolley:
28 x 60 x 51 in., 775 lb.
711 x 1524 x 1295 mm, 352 kg |