Input: |
230 V single phase, 80 A peak, 50/60 Hz |
Output: |
0-200 kV AC peak, 100 mA (bushing output – cable not included) |
Duty: |
Continuous |
Load Rating: |
0.75 µF @ 0.1 Hz
1.5 µF @ 0.05 Hz
3.75 µF @ 0.02 Hz |
Voltmeter: |
0 – 200 kV AC peak, 3.5″ analog display |
Current Meter: |
0 – 200 mA, 3.5″ analog display |
Output Termination: |
0 – 6 µF |
Size & Weight: (W x D x H) |
Controls:
24 x 25.5 x 71 in., 650 lb.
61 x 65 x 180 cm, 295 kg
HV Tank:
59 x 37 x 87 in., 3700 lb.
155 x 93 x 220 cm, 1678 kg |