IEC
IEC 61000-4-29 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement...
Standard Overview
This subsection of IEC 61000 defines test methods for immunity to voltage dips, short interruptions and voltage variations at the DC input power port of electrical or electronic equipment. This test is similar to the IEC 61000-4-11 dips/interrupt test but applies to DC-powered products.
IEC 61000-4-29 applies to low voltage DC power ports of equipment supplied by external DC networks.
The object of IEC 61000-4-29 is to establish a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or voltage variations on DC input power ports.
IEC 61000-4-29 defines:
- The range of test levels
- The test generator
- The test set-up
- The test procedure
The test applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the EUT (equipment under test) rated power is greater than the test generator capacity specified in clause 6.
The ripple at the DC input power port is not included in the scope of this part of IEC 61000. It is covered by IEC 61000-4-17.
Common features for all IEC 61000-4 standards
This standard does not specify the tests to be applied to a particular apparatus or system. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.
IEC 61000-4-29 applies to low voltage DC power ports of equipment supplied by external DC networks.
The object of IEC 61000-4-29 is to establish a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or voltage variations on DC input power ports.
IEC 61000-4-29 defines:
- The range of test levels
- The test generator
- The test set-up
- The test procedure
The test applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the EUT (equipment under test) rated power is greater than the test generator capacity specified in clause 6.
The ripple at the DC input power port is not included in the scope of this part of IEC 61000. It is covered by IEC 61000-4-17.
Common features for all IEC 61000-4 standards
- Pre-set test sequences and test levels
- Immunity tests can be run continuously or in single-step mode to allow close observation of EUT performance.
- Measurements such as voltage and current and recorded at each test step and included in test reports.
- User-guided prompts the operator through the entire test procedure.
- All test sequences are fully customizable by the user if needed to create a custom version or special purpose test variations as desired.
This standard does not specify the tests to be applied to a particular apparatus or system. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.
Products Used in Testing

EMC Partner IMU4000 Immunity Tester 4kV


Pacific Power 3150AFX AC & DC Programmable Power Source
- DC, 15 to 1,200 Hz frequency range
- Accuracy ± 0.01%
- 125 Arms / 62.5 ADC


Pacific Power 3210AGX | AC & DC Load/Power Supply | 21 kVA
- 15 - 1200 Hz
- 1 Phase mode 125 Arms / 62.5Adc
- 0-350 Vac / 0-500 Vdc


Pacific Power 3500 AZX Regenerative AC and DC Power Source | 50 kVA, 50 kW, 3P
- Full power source and sink capability
- Full 100% of current and power rating in both source and sink model
- Parallel configurations for higher power


California Instruments Tahoe | TA0045A1 Power Supply | 45 kVA
- Output: 45kVA, 0-166/333Vrms, 1/3ph
- Frequency Range: 16Hz - 905Hz
- Input Power: 208/600VAC, 3ph


California Instruments Sequoia Series | Regenerative AC Grid Simulator
- 480V overvoltage testing supported
- Non-Linear current waveform programming
- 500uS time resolution for Transients


EMC Partner IMU-MGS Conducted Immunity Generator
- One touch parameter editing in run state
- Impulse stability over long periods
- Intuitive multi touch graphical interface


EMC Partner IMU-MGE Conducted Immunity Test System
- Surge / CWG 4kV / 5 kV / 6kV / 8kV
- Ring Wave 6kV / 8kV
- EFT 4kV / 5kV / 6kV / 7kV


Haefely AXOS8 Compact Conducted Immunity Test System
- 0.2 – 5.0 kV ±10% at coaxial output
- 50 Ohms
- 5 ns ±30%


Haefely AXOS5 Compact Immunity Test System
- Easy to operate with manual and automated test modes, software assisted test preparation
- Pre-defined test routines and visual aided test setups
- Economic & efficient touch screen guarantees reduction of time and effort


California Instruments MX45 AC Power Source
- Output: 45kVA, 0-150/300V, 3ph
- Frequency Range: 40 - 1000Hz
- Input Power: 208/480 ±10%VAC, 3ph


California Instruments CSW5550 Programmable AC/DC Power Source
- Output: 5.5kVA, 0-156/312V, 3ph
- Frequency Range: 40Hz - 5kHz
- Input Power: 187/264Vrms (3 wire), 342/457Vrms (4 wire), 3ph