
IEC
IEC 61000-4-16: Testing and Measurement Techniques – Test for Immunity to Conducted, Common Mode...
Standard Overview
IEC 61000-4-16 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, common mode disturbances in the range d.c. to 150 kHz. The scope of IEC 61000-4-16 is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to the power supply, control, signal and communication ports.
IEC 61000-4-16 defines:
IEC 61000-4-16 is intended to demonstrate the immunity of electrical and electronic equipment when subjected to conducted, common mode disturbances such as those originating from power line currents and return leakage currents in the earthing/grounding system.
IEC 61000-4-16 defines:
- Test voltage and current waveform
- Range of test levels
- Test equipment
- Test set-up
- Test procedures
IEC 61000-4-16 is intended to demonstrate the immunity of electrical and electronic equipment when subjected to conducted, common mode disturbances such as those originating from power line currents and return leakage currents in the earthing/grounding system.
The disturbances produced by 400 Hz mains systems are not included in the scope of this standard. Actual interference due to these disturbance phenomena is relatively rare, except in industrial plants. Product committees should consider whether there is a justification for applying this standard in their product/product family standards (see also Clause 4). This test is not relevant for equipment ports intended to be connected to short cables, having a length of less than 20 m or less.
Advanced Test Equipment Rentals provides a variety of equipment for performing immunity tests and other EMC tests. Check out all of the EMC test equipment we carry for rent or read more about EMC testing.
Products Used in Testing

AE Techron 7224 Linear Power Amplifier
- Frequency Range: DC – 300 kHz
- Gain: Voltage Mode: 20 V
- Max Output Power: 1,100 W RMS


Teseq NSG 4060 Low Frequency Immunity Test System
- Signal generator and integrated power amplifier 15 Hz to 150 kHz
- Meets IEC / EN 61000-4-16 in combination with the Extension Unit
- Meets IEC / EN 61000-4-19 and other standards


EMC Partner IMU C-SHORT Common Mode Short Duration Testing Extension
- IEC 61000-4-16 Standard
- Testing capabilities that find conducted immunity
- Common mode extension


EMC Partner IMU-MGS C Common Mode Extension
- IEC 61000-4-16 latest edition standard
- Frequency range of 0 Hz to 150 kHz
- Adjustable sweep time


EMC Partner CN16T8 DC Coupling-Decoupling Network
- DC Line CDN for 8 Lines (4 pairs)
- ​EUT / AE connector (RJ45)
- IEC 61000-4-16 standard


EMC Partner IMU-MGS Conducted Immunity Generator
- One touch parameter editing in run state
- Impulse stability over long periods
- Intuitive multi touch graphical interface


EMC Partner IMU-MGE Conducted Immunity Test System
- Surge / CWG 4kV / 5 kV / 6kV / 8kV
- Ring Wave 6kV / 8kV
- EFT 4kV / 5kV / 6kV / 7kV
