ETS-Lindgren MF-9F RF Leak Detector/Attenuation Meter Kit
The ETS-Lindgren MF-9F RF Leak Detector/Attenuation Meter Kit is designed to simplify the performance evaluation of shielding enclosures. ETS-Lindgren MF-9F kits offer the ability to make measurements for military and commercial standards. The ETS-Lindgren MF-9F receiver module can store up to 63 attenuation levels per frequency to be downloaded to a PC. Windows compatible software is included for viewing, processing, and printing data. The Model MF-9F-LF is intended for testing at lower frequencies: 10 kHz, 156 kHz, 1 MHz, 10 MHz. The Model MF-9F-HF is intended for testing at higher frequencies: 8 MHz, 16 MHz, 32 MHz, 64 MHz. The Model MF-9F-VHF is intended for testing at a 128 MHz frequency. All transmitters and receivers feature backlit LCD displays, easy-to-use keypads, and rechargeable NiMh batteries. The receiver's LCD display frequency, attenuation level and battery condition. The keypad can be used to select MIL-STD or EN testing, and to set an attenuation threshold level for activating an audio alarm. The receiver also has USB port to download data to a PC. The transmitter LCD displays frequency and battery condition.
Electrical | MF-9F | LF Antenna | HF Antenna | VHF Antenna |
---|---|---|---|---|
Frequency Range | N/A | 10 KHz 156 KHz 1 MHz 10 MHz |
8 MHz 16 MHz 32 MHz 64 MHz |
128 MHz |
Frequency Accuracy | 5 ppm/10 Maximum | N/A | N/A | N/A |
Dynamic Range: MIL-STD-285 | N/A | 120 dB | 110 dB | 130 dB |
Dynamic Range: NSA 65-6 | N/A | 130 dB | 120 dB | 130 dB |
Dynamic Range: IEEE STD-299 | N/A | 130 dB | 120 dB | 130 dB |
Dynamic Range:EN 50147-1 | N/A | 130 dB | 120 dB | 130 dB |
Attenuation Accuracy | ± 2 dB | ± 2 dB | ± 2 dB | ± 2 dB |
Output Power | N/A | 2 W Maximum | 2 W Maximum | 2 W Maximum |
Antenna | N/A | 2 Layer PCB Antenna | 1 Layer PCB Antenna | External Connector: BNC 50 Ω |
Display | 128 x 64 LCD Matrix Display with Background Light | N/A | N/A | N/A |
Memory | 63 Memory Locations for Attenuation Values for Each Frequency | N/A | N/A | N/A |
Preset Functions | Attenuation Limit in dB | Attenuation Limit in dB | Attenuation Limit in dB | Attenuation Limit in dB |
Calibration | Auto Calibration | Auto Calibration | Auto Calibration | Auto Calibration |
Power Supply (Both) | 6 x 1.2 Volt NiMh Battery (1) | 6 x 1.2 Volt NiMh Battery (1) | 6 x 1.2 Volt NiMh Battery (1) | 6 x 1.2 Volt NiMh Battery (1) |
Battery Life: Transmitter | 10 to 15 Hours | 10 to 15 Hours | 10 to 15 Hours | 10 to 15 Hours |
Battery Life: Receiver | 15 to 20 Hours | 15 to 20 Hours | 15 to 20 Hours | 15 to 20 Hours |
- Shielding Attenuation Measurements per:
- MIL-STD-285
- NSA 65-6
- IEEE STD-299
- EN 50147-1
- Stores/Downloads up to 63 Attenuation Levels per Frequency
- Includes Windows Compatible Software
- Easy-to-Use, Portable
- MIL-STD-285
- NSA 65-6
- IEEE STD-299
- EN 50147-1