Tektronix TDS5104B 4 Channel 1 GHz 5GS/s Digital Oscilloscope
The Tektronix TDS5104B Digital Oscilloscope offers the industries first easily customizable oscilloscope user interface. MyScope control windows is a revolutionary new feature that allows you to build your own control windows with only the controls, features, and capabilities that you care about and are important in your job. For the first time, you can pull all the functionality you need from all the various parts of the oscilloscope into one control window, effectively creating your own personalized toolbox of oscilloscope features.
No longer do you need to search through menus for features or re-learn how to drive the oscilloscope after a break from the lab. MyScope control windows enable you to spend your valuable time focused on the task at hand rather than navigating menus on your oscilloscope. And creating these custom control windows isn't a long drawn-out or complex process. They are easily created in a matter of minutes using a simple, visual, drag and drop process. Once created, these custom control windows are easily accessed through a dedicated MyScope button and menu selection on the oscilloscope button/menu bar, just like any other control window.
Vertical System | |
---|---|
Input Channels | 4 |
Analog Bandwidth (-3 dB) 5 mV/div - 1 V/div | 1 GHz |
Calculated Rise Time 5 mV/div (typical) | 300 ps |
Hardware Bandwidth Limits | 150 MHz or 20 MHz |
Input Coupling | AC, DC, GND |
Input Impedance, 1 MΩ | ±1% |
Input Impedance, 50 Ω | ±2.5% |
Input Sensitivity, 1 MΩ | 1 mV/div to 10 V/div |
Input Sensitivity, 50 Ω | 1 mV/div to 1 V/div |
Vertical Resolution | 8-bits (>11-bits w/ averaging) |
Max Input Voltage, 1 MΩ | 150 V CAT I, ≤ 400 V peak. Derate at 20 dB/decade to 9 VRMS above 200 kHz |
Max Input Voltage, 50 Ω | <100 mV/div <1 VRMS |
DC Gain Accuracy | 1.5% with offset set to 0 V |
Offset Range, 1 MΩ | 1 mV/div - 99.5 mV/div ±1 V |
Offset Range, 50 Ω | 1 mV/div - 50 mV/div ±0.5 V |
Channel-to-channel Isolation for Any Two Channels at Equal Vertical Scale | ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth |
Timebase System | |
---|---|
Timebase Range | 200 ps/div to 1000 s/div |
Timebase Delay Time Range | (s/div " 10) to 1000 s |
Channel-to-channel Deskew Range | ±75 ns |
Timebase Accuracy | 15 ppm |
Delta Time Measurement Accuracy | (0.06/sample rate + 15 ppm " |Reading|)RMS |
Trigger Jitter (RMS) | 8 psRMS (typical) |
Long Term Sample Rate and Delay Time Accuracy | ±15 ppm over any ≥1 ms interval |
- 1 GHz Bandwidth Model
- 4 Channel Models
- 5 GS/s Sample Rate
- Up to 16 M Record Length
- 100,000 wfms/s Maximum Waveform Capture Rate
- MyScope Custom Control
- Windows Enhance Productivity
- Right Mouse Click Menus for Exceptional Efficiency
- OpenChoice® Platform with Windows 2000 Delivers Built-in Networking and Analysis
- Small Footprint/Light Weight
- 10.4 in. Bright Display
- Suite of Advanced Triggers
- Communication Mask Testing
- Pass/Fail Limit Testing
- Remote Viewing and Control
- E-mail on Event
- CD-RW Drive
- Interoperability with Tektronix Logic Analyzers
- GPIB Controller
- Digital Design and Debug
- Mask Testing for Telecom/Datacom/Video Standards
- Investigation of Transient Phenomena
- Power Measurements
- Video Design and Debug
- DVD, Jitter and Timing, Spectral Analysis
- Automotive Electronics
- Manufacturing Test
- Electro-mechanical
- Bio-medical
- Industrial Control