Narda SMARTS Surveillance Monitor | 2 MHz - 100 GHz
Discontinued
The Narda SMARTS Surveillance Monitor has been discontinued.
Narda 8820 (500 MHz to 18 GHz) and 8825B (500 MHz to 100 GHz) use broadband thermocouple detectors to monitor the electric field. Both models sound an alarm only when the average power level is exceeded and are ideal for use with microwave systems where pulse modulation is normally employed.
SMARTS monitors are available in a totally nonmetallic, weatherproof enclosure for outdoor mounting. This enclosure will protect the SMARTS from dust, rain, or heavy seas.
The Narda SMARTS Surveillance Monitor, 8820 is part of the Narda Safety Test Solutions SMARTS Series.
Model no. | 8810 | 8815 | 8820 | 8825b |
Frequency range | 2 to 30 MHz | 10 to 500 MHz | 0.5 to 18 GHz | 0.5 to 100 GHz |
Frequency sensitivity | ±1.5 db | ±2.0 db | 3.0 dba | 4.5 db 0.5 - 50 GHza 6.0 db 0.5 - 100 GHza |
alarm threshold | 10 % of standardb | 0.1 mw/cm2 | 1.0 mw/cm2 | 0.5 mw/cm2 |
overload cw peak |
60 mw/cm2 60 w/cm2 |
300 mw/cm2 100 w/cm2 |
||
3 db intercept angle | >180° | >180° | >180°C | >180°C |
temperature operating non-operating |
-10°c to +55°c -40°c to + 75°c |
|||
batteries circuitd fail-safee |
9v lithium (supplied) 3v lithium (supplied) |
|||
weight (approx) | 24 oz. (0.7 kg) | |||
calibration frequenciesf | 2, 3, 10 and 30 MHz | 10, 30, 100, 300, 400 and 500 MHz |
8.2f GHz | 8.2f GHz |
accessories supplied | operation manual, j1 and j2 mating connectors |
Notes:
a Peak to peak. The threshold can be factory set to provide optimum performance over a specific band of interest.
b The alarm threshold is proportionate to IEEE C95.1-1991 Standard and varies over the 2 to 30 MHz band. The threshold is 0.9% of
the H field Maximum Permissible Exposure (MPE) from 3 to 30 MHz and equal to 10% of the E field MPE from 2 to 30 MHz.
(Controlled Environments)
c The 3 dB intercept angle is >180° with the E field tangential to the mounting plane and >165° with the E field perpendicular to the
mounting plane.
d The rated life is two years. It is recommended that this battery be replaced annually during calibration.
e The fail-safe battery has a rated life of 5 to 10 years. It is recommended that it be checked annually during calibration and replaced
every three years.
f Other calibration frequencies available for narrow band applications. Contact the factory.
- 2 MHz to 100 GHz Detection
- Audible, Visible, Remote Alarms
- Continuous, Automatic Monitoring
- Fail-safe
- Requires No Operator
- Indoor and Outdoor Models