The Fluke Ti30 Thermal Imager can be used to make an effective predictive maintenance program easy, fast, accurate and affordable. This thermal imager can be utilized for scheduled inspections, quick spot checks and everything in between. The Fluke Ti30 Thermal Imager uniquely supports thermography inspection routing. After the first inspection, the images taken can be combined in the InsideIR™ software with location names and temperature data, and uploaded to the imager for use as a routing guide. During subsequent inspections, an on-camera display prompts the user exactly where to take images - improving accuracy. The new images are easily compared to previous scans, helping to identify potential problems before they cause failure.
Maintenance personnel can quickly and easily capture high-quality infrared images using the Fluke Ti30 Thermal Imager. Because the camera collects 12 bits of information for every one of its 19,200 pixels, users in the field can simply point, focus and shoot. With a properly composed, well-focused image, all further analysis can be performed with the InsideIR software in the quiet, comfort and safety of an office.
Features
- Easy to use; just point, focus and shoot
- Scans quickly and smoothly
- Displays thermal image and temperature
- Has a temperature measurement range of -10 °C to 250 °C
- Has a laser sighting aid that can easily be turned on or off
- Includes professional analysis and reporting software - InsideIR
- Has industry leading battery life (> 5 hours continuous use)
- Runs off both a rechargeable battery pack and standard or rechargeable alkaline AA batteries
Specifications
Detector |
Detector Type |
120 x 160 uncooled focal plane array |
NETD (Thermal Sensitivity) |
200 mK |
Thermal |
Temperature Range |
-10 to 250 °C (14 to 482 °F) |
Accuracy |
±2% or ±2 °C (±3 % or 3 °C from -10 to 0 °C) |
Optical |
Optical Resolution |
90:1 |
Slit Response Optical Resolution |
225:1 |
Minimum Diameter Measurement Spot |
7 mm (0.27 in) at 61 cm (24 in) |
Field of View (FOV) |
17 ° Horizontal x 12.8 ° Vertical |
Target Sighting |
Single laser (Meets IEC Class 2 & FDA Class II requirements) |
Controls and Adjustments |
Focus |
Focusable, 61cm (24 in) to infinity |
Temperature Scale |
°C or °F selectable |
Palettes |
Gray, Ironbow or Rainbow |
Measurement Modes |
Automatic, Semi-Automatic or Manual |
LCD Backlight |
Bright, Dim, Off-Selectable |
Adjustable Emissivity |
0.10 to 1.00 by 0.01 |
Reflected Background Temperature |
-50 to 460 °C (-58 to 860 °F) |
Environmental |
Ambient Operating Temperature |
-10 to 50 °C (14 to 122 °F) |
Relative Humidity |
10 to 90% Non-Condensing |
Storage Temperature |
-25 to 70 °C (-13 to158 °F) (without batteries) |