Fluke I2000 Flex AC Current Clamp
This oscilloscope probe is an accessory and is only available to rent with an oscilloscope.
See All Oscilloscopes
The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
Electrical Specifications | |
Current Ranges: | 20 A |
200 A | |
2000 A | |
AC rms | |
Output Sensitivity (AC-coupled) | 100 mV |
10 mV | |
1 mV | |
1 mV per A | |
Load Impedance | 100 kΩ minimum |
Accuracy | at +25 °C± 1 % of range (45 Hz to 65 Hz) |
Linearity | 10% to 100% of range ± 0.2 % of reading |
Noise | 8 mV ac rms (30 A) |
2 mV ac rms (300 A, 3000 A) | |
Frequency Range | 10 Hz to 20 kHz (-3 dB) |
Phase Error | < ± 1º (45 Hz to 65 Hz) |
± 10º (at 20 kHz) | |
Position Sensitivity | with cable > 25 mm from the coupling ± 2 % of range |
External Field | with cable > 200 mm from the head ± 1 % of range |
Power Supply | 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator |
Temperature Coefficient | ± 0.08% of reading per °C |
Working Voltage | see Safety standards section 600 V AC rms or DC |
General Specifications | |
Head Circumference | 610 mm (24 in) |
Head Cable Diameter | 14.3 mm (0.56 in) |
Head Bend Radius | 38.1 mm (1.5 in) |
Cable Length (Head to Electronics) | 2 m (6.56 ft) |
Output Connection | Molded 4 mm safety plugs (not integrated) |
Operating Temperature Range | 0°C to +70°C (32°F to 158°F) (head and electronics) |
Storage Temperature Range | -40°C to +105°C (-40°F to 221°F) (head) |
-20°C to +85°C (-4°F to 185°F) (electronics) | |
Operating Humidity | 15% to 85% (non-condensing) |
Weight | 180 g (6.34 oz) (head) |
190 g (6.70 oz) (electronics) | |
Safety Standards | EN 61010-1: 2001 |
EN 61010-2-032: 2002 | |
EN 61010-031: 2002 | |
600 Vrms, Category III, Pollution Degree 2 | |
Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz. | |
EMC Standards | EN 61326: 1998 +A1, A2, & A3 |
Dimensions | HxWxD 116 mm x 68.5 mm x 30 mm (4.56 in x 2.69 in x 1.18 in) |
- Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm
- CAT III 600V safety rating