DV Power BLU360V Battery Load Unit
DV Power BLU360V Battery Load Unit series are stand-alone or PC-controlled battery capacity test instruments based on the state-of-the-art technology. Their design is deploying the most advanced power electronics solutions with coolers and fans integrated into the device.
DV Power BLU360V devices are lightweight and developed to meet a customer's wide ranging test procedure requirements (standardized as well as customized). Using a DV Power BLU device, the capacity test is performed in an accurate, user-friendly way in accordance with the battery testing standards (IEEE 450-2010 / 1188-2005 / 1106-2005, IEC 60896-11/22 and other relevant standards).
The capacity test/discharge can be performed at constant current, constant power, constant resistance or in accordance with a pre-selected load profile. The discharge test can be conducted even in a case a battery remains connected to the load – by measuring the load current during the process.
The table below presents the maximal currents for various battery voltage ranges for the required minimal cell voltage of 1.75 V.
Maximum discharge current (A) | ||||||
---|---|---|---|---|---|---|
Battery voltage (V) | BLU100A | BLU200A | BLU340A | BLU220T | BLU360V | |
Nom. | Min/Max | |||||
6 | 5,25 | 40 | 50 | 50 | 100 | 50 |
7,05 | ||||||
12 | 10,5 | 80 | 100 | 100 | 200 | 100 |
14,1 | ||||||
24 | 21,0 | 160 | 200 | 160 | 340 | 160 |
28,2 | ||||||
48 | 42.0 | 160 | 200 | 160 | 340 | 160 |
56.4 | ||||||
60 | 52.5 | 120 | 120 | 160 | 275 | 160 |
70.5 | ||||||
110 | 96.3 | 110 | 120 | 160 | – | 160 |
129.3 | ||||||
120 | 105,0 | 100 | 120 | 150 | – | 150 |
141.0 | ||||||
220 | 192.5 | 55 | 75 | 110 | – | 110 |
258.5 | ||||||
240 | 210.0 | 50 | 70 | 100 | – | 100 |
282.0 | ||||||
480 | 300 | – | – | – | – | 50 |
480 | ||||||
Weight (kg / lbs) | 12.8 / 28 | 14.5 / 32 | 20.6 / 45.4 | 15.1 / 33 | 20.6 / 45.4 | |
Max Power (kW) | 14.2 | 19.7 | 28.4 | 19.4 | 28.4 |