Related Products

ETS-Lindgren 95236-1 Bulk Current Injection Probe


Teseq CT 419-5 Current Transformer for IEC / EN 61000-4-19
- Coupling transformer designed for IEC/EN 61000-4-19
- Frequency range 2 kHz to 150 kHz
- 4 mm banana sockets


EMC Partner IMU C-SHORT Common Mode Short Duration Testing Extension
- IEC 61000-4-16 Standard
- Testing capabilities that find conducted immunity
- Common mode extension


PMM CDN-AF2 Coupling Decoupling Network
- 150 kHz - 230 MHz
- 4 mm Safety Lab Connectors
- 250 V AC / 250 V DC


Fischer Custom Communications BCICF-1 Calibration Fixture
- Excellent VSWR over a broad bandwidth: <2:1 over the frequency range of 10kHz – 400 MHz when the probe is in fixture
- Accommodates a wide variety of Bulk Current Injection Probes that operate between 10 kHz – 400 MHz


Solar 9142-1N Bulk Current Injection Probe | 2 MHz – 450 MHz
- Bulk current injection probe
- Frequency range of 2 MHz to 450 MHz
- Maximum input power of 200 W


Com-Power CLCE-438 RF Current Probe | 9 kHz – 400 MHz
- Frequency range of 9 kHz to 400 MHz
- Suitable for CISPR, MIL-STD-461, and DO-160
- Individual calibration


Com-Power CDN-S4 4 Wire Coupling/Decoupling Networks (CDN)
- For Signal Lines
- Frequency Range - 150 kHz - 80 MHz
- Meets EN 61000-4-6 requirements


Pearson Electronics 110 Current Monitor Probe | 1Hz – 20MHz
- Current monitor probe
- Robust peak current capacity of 5 kA
- Frequency response reaching up to 20 MHz


AH Systems ICP-621 Injection Current Probe | 10 kHz – 100 MHz
- Broad frequency range of 10 kHz to 100 MHz
- Individually calibrated
- Split type clamp-on design


Com-Power CDN-AF2 Coupling/Decoupling Network (CDN)
- For Signal Lines
- Frequency Range - 150 kHz - 80 MHz
- Meets EN 61000-4-6 requirements


Teseq Mil-Std-461 CS114 10kHz - 400 MHz Conducted Susceptibility Test System
- Signal generation: NSG 4070-0
- Modulator: included in NSG 4070-0
- Power meter: 3x included in NSG 4070-0


Fischer Custom Communications F-33-2 Current Probe | 1kHz - 250MHz
- Compact probes with an external diameter of roughly 71 mm and an internal diameter of 32 mm
- Frequency spectrum from 1 kHz to 250 MHz
- BNC connector


Solar 9123-1 Current Monitor Probe | 10 kHz – 500 MHz
- Bulk current injection probe for EMI testing
- Clamp-on design
- Frequency range of 10 kHz to 500 MHz


EM Test LD200S19 Load Dump Generator
- Load Dump generator as per Toyota Specification
- Generates pulses Test 1, Test 2 and Test 3
- Built-in coupling network for 60V/25A DC


Schwarzbeck CDN-S25-SUBD
- Part of the coupling decoupling network series
- For conducted common mode immunity testing according to IEC 61000-4-6
- Frequency range of 10 kHz to 230 MHz


Frankonia MTS-800 Magnetic-Field Low-Frequency Emission and Immunity Test System
- Frequency range for emission and immunity measurements: DC – 250 kHz
- 800W precision power amplifier, signal generator and spectrum analyzer in one compact unit
- All instruments may as well be used as stand-alone devices


Teseq PA 5840 Automotive Power Amplifier/Battery Simulator
- Large inrush current capability
- Capacitive stability mode
- High bandwidth up to 150 kHz


Com-Power CDN-AF4 Coupling/Decoupling Network (CDN)
- For Signal Lines
- Frequency Range - 150 kHz - 80 MHz
- Meets EN 61000-4-6 requirements


LeCroy CP150 Current Probe
- Current probe
- Compact design
- Broad bandwidth


Teseq NSG5200 Automotive Transient Test System


Teseq (Schaffner) KEMA 801A Decoupling Clamp
- Decoupling Network/ RF attenuation clamp
- As specified in IEC/EN 61000-4-6
- Very efficient coupling


PMM RAD-IS/3G-602 Radiated Immunity System


EM Test PFS 200N Series Automotive Power Fail Simulator
- Standalone test generator for voltage dips and interruptions
- Rise/fall time <1us
- Electronic short-circuit protection


AE Techron T2000 Low-Frequency Conducted Susceptibility Transformer
- Frequency response: 10 Hz to 250 kHz.
- Turns ratio: 2:1 step down
- Audio power: 200W